Overview
Model EPV enclosure protection vents are self-seating
gravity controlled, low pressure relief valves designed to
ventilate excessive enclosure pressures that are created by
the Rapid Exchange® process, or the failure of enclosure
pressure control devices. Each vent features a seamless
cap, a spark arresting (SA) style exhaust element, a
friction-free valve assembly, a base and a mounting hub.
The mounting hub, along with associated pipe fi ttings,
permits direct mounting through a round cutout on the
top or side of a protected enclosure. This device functions
in conjunction with Pepperl+Fuchs enclosure protection
systems, to reduce the hazardous (classifi ed) area rating
within protected enclosure(s), in accordance with the
NEC - NFPA 70, Article 500, NFPA 496 and ISA 12.4.
In addition, this device protects enclosures from all limited
sources of pressure relief, regardless of source - i.e.
unrelated pneumatic equipment, such as analyzers or
other process control or measurement instrumentation.
gravity controlled, low pressure relief valves designed to
ventilate excessive enclosure pressures that are created by
the Rapid Exchange® process, or the failure of enclosure
pressure control devices. Each vent features a seamless
cap, a spark arresting (SA) style exhaust element, a
friction-free valve assembly, a base and a mounting hub.
The mounting hub, along with associated pipe fi ttings,
permits direct mounting through a round cutout on the
top or side of a protected enclosure. This device functions
in conjunction with Pepperl+Fuchs enclosure protection
systems, to reduce the hazardous (classifi ed) area rating
within protected enclosure(s), in accordance with the
NEC - NFPA 70, Article 500, NFPA 496 and ISA 12.4.
In addition, this device protects enclosures from all limited
sources of pressure relief, regardless of source - i.e.
unrelated pneumatic equipment, such as analyzers or
other process control or measurement instrumentation.